Australian product supportLocal experts, here to help.
Fast tracked deliveryQuick dispatch Australia-wide.
3 year manufacturer warrantyBuilt to last. Backed with confidence.
Secure checkoutSafe, encrypted and trusted.
Free Shipping
Skip to product information

Hikivision DS-K2602-GN/Aust Two Door Access Controller

  • Sku: DS-K2602-GN/Aust
  • Vendor: SecurityAustralia
$742.00 AUD
 per 
Tax included.
Shipping calculated at checkout.
In stock - Ready to ship
Free shipping on orders over $100. Usually ships within 1 business day when available.
Quick Buying Summary

The DS-K2602-GN delivers centralised 2-door access control for commercial and enterprise installations requiring high-capacity credential management and flexible reader integration. Supporting up to 100,000 cards (expandable to 200,000) and 300,000 events, it connects via TCP/IP and offers both RS-485 and Wiegand interfaces for broad compatibility with existing hardware.

Why This Model

  • Scalable card storage: With capacity expandable to 200,000 cards and 600,000 events, this controller grows with your site without requiring a hardware upgrade.
  • Dual reader protocol support: Simultaneous RS-485 and Wiegand (W26/W34) interfaces mean it integrates with a wide range of third-party readers already installed on site.
  • Comprehensive I/O for real-world sites: 4 alarm inputs, 4 alarm relays, door sensors, exit buttons, case inputs, and a tamper alarm give integrators full control over door hardware and external devices from a single unit.
2-Door Control TCP/IP RS-485 & Wiegand 100,000 Cards 300,000 Events 4 Alarm Inputs Tamper Alarm

Downloads & Resources

User Manual - DS-K2600 Series Access Controller
Datasheet - DS-K2600-G Series
Quick Start Guide - DS-K2600 Series
Product Spec Sheet (PDF)  

Need help choosing?

Click to ask a question - same day response (~2 hours during business hours)

Free shipping Enjoy free shipping when your order exceeds $100. Fast dispatch Orders are dispatched within the next business day. Best local support in Aus We back all products with manufacturer warranty support. Official Australian stock Genuine products with local warranty support.

Product Overview

Model: DS-K2602-GN/Aust

Who This Is For

When managing controlled entry across 2 doors with a mix of card readers and legacy Wiegand hardware is the priority, the DS-K2602-GN/Aust is the controller installers reach for. Designed for commercial buildings, schools, strata complexes, and light industrial facilities, this unit handles up to 100,000 card holders and 300,000 access events, making it a practical fit for mid-sized deployments where a single-door panel falls short but a multi-panel enterprise system is overkill. With 4 RS-485 ports and 4 Wiegand (W26/W34) interfaces on the downlink side, it connects to a wide range of existing readers without forcing a full hardware refresh. TCP/IP uplink communication means it integrates into standard network infrastructure and can be managed centrally via Hikvision's access control software. Security contractors specifying fit-outs for office tenancies, school administration areas, or warehouse entry points will find the DS-K2602-GN/Aust covers the core two-door brief without unnecessary complexity.

Download Product Datasheet (PDF)

What This Controller Actually Does

Two-Door Control in One Unit

Manages 2 independent door lock relays from a single controller board. Each door gets its own door sensor input and exit button input, so entry, exit, and door-held alerts operate independently without cross-door interference.

Large Card and Event Storage

Stores 100,000 card records (expandable to 200,000) and 300,000 access events (expandable to 600,000) onboard. The controller keeps operating and logging locally even if the network drops, protecting audit trail continuity.

Flexible Reader Compatibility

4 RS-485 ports and 4 Wiegand (W26/W34) downlink interfaces mean the controller works with a broad range of card readers, keypads, and biometric devices - including third-party hardware already installed on site.

Network-Based Management

TCP/IP uplink connects the controller directly to a site LAN. This allows centralised user management, remote configuration, and event monitoring via Hikvision access control software without needing a serial communication run back to a central panel.

Alarm and Tamper Integration

4 alarm inputs, 4 alarm relay outputs, 4 case inputs, and a dedicated tamper alarm input allow the controller to interface with wider security systems. Alarm relays can trigger external devices or relay alerts back through the network to a monitoring platform.

Status at a Glance

7 onboard LED indicators cover RS-485 communication status (x2), power supply, exit button, lock status, door magnetic sensor, and running status. On-site diagnostics during commissioning or fault-finding do not require a laptop connection.

Who Buys This Model

  • Security installers on commercial fit-outs: Specifying a two-door access solution for office tenancies or building lobbies where TCP/IP management and a large card database are required without the cost of a full enterprise controller.
  • School and education facilities managers: Managing staff and contractor access across administration and secure areas, where 100,000 card capacity covers full staff populations with room to grow and the event log supports compliance reporting.
  • Warehouse and light industrial operators: Controlling entry and exit at loading dock doors or internal secure rooms, where Wiegand reader compatibility lets them retain existing proximity card hardware while upgrading the controller backend.
  • Strata and property managers: Running two-door access for car park entry and building lobby combinations, where onboard event storage keeps logs available even during internet outages and the tamper alarm adds cabinet security.

Honest Assessment

The DS-K2602-GN/Aust handles the two-door access control brief competently. The combination of a large onboard card database, expandable event storage, and dual downlink protocols (RS-485 and Wiegand) gives installers genuine flexibility when working with mixed-hardware sites. TCP/IP uplink keeps it compatible with modern network-managed deployments, and the 7-indicator status panel speeds up on-site commissioning. The wide operating temperature range of -20°C to +65°C is a practical advantage for installations in plant rooms or unconditioned spaces. Where this unit reaches its natural limit is door count - if a project requires 4 or more doors, a higher-channel controller will be more cost-effective per door. It also does not include a built-in power supply for lock hardware beyond the control board itself, so lock power must be budgeted separately. Available through Security Australia, it suits two-door commercial and institutional projects well within those parameters.

Before You Buy

Power Planning: The DS-K2602-GN/Aust operates at DC 12V/1A for the controller board itself (drawing up to 4W without load). Lock hardware, readers, and alarm devices draw from the load side and can push total consumption to 100W. Confirm your power supply is appropriately rated for the combined lock, reader, and auxiliary load before installation - underpowered supplies are a common cause of lock relay faults and false door-held alerts.

Wiegand Protocol Check: Confirm whether your existing or planned readers output W26 or W34 before wiring. The controller supports both, but mismatched protocol configuration between the reader and the controller setup in software is a frequent commissioning issue. Set and confirm the Wiegand format in the access control software before finalising installation.

Quick Fit Check

  • Good match if: You are controlling exactly 2 doors and need compatibility with existing Wiegand readers - the 4 Wiegand interfaces give you in/out reader coverage on both doors without additional hardware.
  • Good match if: Your site has a large staff or card-holder population - 100,000 card records onboard (expandable to 200,000) covers enterprise-scale user databases that would overflow smaller single-door panels.
  • You may need a different model if: Your project covers 4 or more controlled doors - a higher-channel access controller will deliver a lower cost-per-door and simplify cabling across the expanded door count.

Key Features & Technical Specifications

Model
DS-K2602-GN/Aust
Door Count
2
Card Storage
100,000 (expandable to 200,000)
Event Log Storage
300,000 (expandable to 600,000)
Memory
16M
Processor
32-bit
Uplink Communication
TCP/IP Network Interface and RS-485
Downlink Communication
RS-485 x4 and Wiegand W26/W34 x4
Output Interface
Lock Relay x2, Alarm Relay x4
Input Interface
Alarm Input x4, Door Sensor x2, Exit Button x2, Case Input x4, Tamper Alarm x1
Status Indicators
7 LEDs - RS-485 communication x2, power supply, exit button, lock status, door magnetic, running status
Working Voltage
DC 12V / 1A
Power Consumption
4W (without load); 100W (with load)
Operating Temperature
-20°C to +65°C
Operating Humidity
10% to 90% non-condensing

Real-World Scenarios

Office Tenancy Entry and Server Room

A commercial tenancy needs controlled access at the main entry and a separate IT server room. 1 controller covers both doors, with individual door sensor and exit button inputs per door keeping each point independently monitored and logged.

School Administration Wing

An upgrade to a school's administration block replaces mechanical keys with card access on the front entry and principal's office. The 100,000-card database handles full staff and contractor rosters well above typical school population sizes.

Warehouse with Legacy Readers

A warehouse is upgrading its access controller but retaining existing proximity readers already wired in. Wiegand W26/W34 downlink compatibility means the existing reader hardware connects directly without rewiring or replacing panels at each door.

Strata Car Park and Lobby

A residential strata building controls car park boom gate entry and the ground-floor lobby on a single controller. TCP/IP uplink lets the strata manager update card holder records remotely without an on-site visit when residents move in or out.

Plant Room in Unconditioned Space

The controller is mounted in a mechanical plant room subject to temperature extremes. Its -20°C to +65°C operating range keeps it functional in hot Australian summers or cold-store adjacent environments without requiring a climate-controlled enclosure.

How It Compares

  • Choose this if: Your project is a defined two-door deployment where Wiegand reader compatibility, a large card database, and TCP/IP management are all required - this controller covers all three without over-specifying.
  • You may need a different model if: You need to manage 4 or more doors - a higher-channel access controller will reduce the number of panels, simplify the network topology, and lower the overall per-door cost across larger projects.
  • Pairs well with: A compatible Hikvision card reader or biometric reader on the downlink side, and a dedicated access control power supply unit sized to handle the combined lock and reader load.

Common Questions

  1. Will this controller work with my existing Wiegand card readers?

    Yes. The DS-K2602-GN/Aust supports both W26 and W34 Wiegand protocol on its 4 downlink interfaces. Most proximity card readers, keypad readers, and many biometric readers output one of these two formats. Confirm the output protocol of your existing readers before installation and match the configuration in the access control software accordingly.
  2. How many card holders can this controller store?

    100,000 card records onboard, expandable to 200,000. For most commercial, education, and strata applications this is well above operational requirements. The event log stores 300,000 records (expandable to 600,000), meaning access history is retained locally even during extended periods without network connectivity.
  3. Does this controller need to stay connected to the network to grant access?

    No. The DS-K2602-GN/Aust operates independently once card data is loaded. The 32-bit processor and 16M onboard memory allow the controller to validate cards and operate door relays locally. Network connectivity is used for configuration, event upload, and card management - not for real-time access decisions.
  4. What power supply does this unit require?

    DC 12V at 1A for the controller itself. Without any connected load the unit draws under 4W, but with locks, readers, and alarm devices on the load side total consumption can reach 100W. A dedicated access control power supply with sufficient capacity and battery backup should be planned as a separate line item in the installation.
  5. Can I expand this controller beyond 2 doors later?

    No. The DS-K2602-GN/Aust is a fixed two-door controller. Its lock relay outputs are hardware-limited to 2 doors. If a project is likely to grow beyond 2 controlled doors, specifying a higher-channel controller from the outset avoids replacing the panel entirely. The Security Australia range includes multi-door controller options suited to larger deployments.
  6. Does this controller support anti-passback or time-based access schedules?

    These features depend on the access control software platform used in conjunction with the controller hardware. The DS-K2602-GN/Aust is designed to operate within Hikvision's access control ecosystem where schedule-based permissions, anti-passback zones, and multi-door interlock rules are configured at the software level rather than the controller itself. Confirm feature availability with your software platform before specifying.
  7. What does the tamper alarm input do?

    It detects physical interference with the controller enclosure. When the enclosure is opened without authorisation, the tamper alarm input triggers - this event is logged locally and can be transmitted via the TCP/IP uplink to raise an alert in the monitoring software. It is a standard compliance requirement on many commercial and government access control installations.

Cabling Considerations

  • Network Uplink: Standard Cat5e or Cat6 to your LAN switch for TCP/IP communication. Use a shielded cable in environments with electrical interference near switchboards or plant equipment.
  • RS-485 Runs: Use twisted-pair shielded cable for RS-485 reader connections. Maximum recommended RS-485 run length is typically 1,200m, though shorter runs reduce latency and interference risk. Terminate the RS-485 bus correctly at both ends to prevent communication errors.
  • Wiegand Runs: Wiegand signal runs are distance-sensitive. Keep Wiegand cable runs under 150m and use shielded multi-core cable. Longer runs can introduce signal degradation that causes inconsistent card reads.
  • Lock Wiring: Run lock power cabling separately from data cabling. Inductive load from electromagnetic locks can introduce noise on data lines if bundled together. Size lock power cabling to the draw of the specific lock hardware being installed.

Downloads & Resources

What This Product Does

The DS-K2602-GN delivers centralised 2-door access control for commercial and enterprise installations requiring high-capacity credential management and flexible reader integration. Supporting up to 100,000 cards (expandable to 200,000) and 300,000 events, it connects via TCP/IP and offers both RS-485 and Wiegand interfaces for broad compatibility with existing hardware.

Why This Model

  • Scalable card storage: With capacity expandable to 200,000 cards and 600,000 events, this controller grows with your site without requiring a hardware upgrade.
  • Dual reader protocol support: Simultaneous RS-485 and Wiegand (W26/W34) interfaces mean it integrates with a wide range of third-party readers already installed on site.
  • Comprehensive I/O for real-world sites: 4 alarm inputs, 4 alarm relays, door sensors, exit buttons, case inputs, and a tamper alarm give integrators full control over door hardware and external devices from a single unit.
2-Door Control TCP/IP RS-485 & Wiegand 100,000 Cards 300,000 Events 4 Alarm Inputs Tamper Alarm

Downloads & Resources

User Manual - DS-K2600 Series Access Controller
Datasheet - DS-K2600-G Series
Quick Start Guide - DS-K2600 Series
Product Spec Sheet (PDF)  

Not sure if this suits your site?

Ask our team before ordering. We can help confirm lens choice, recorder compatibility, mounting accessories and project quantities.

Downloads

Get Product Help

Ask our team before ordering. We can help confirm lens choice, recorder compatibility, mounting accessories and project quantities.

Shipping & Warranty

3 Years Manufacturer Warranty

All IP cameras and recording devices (NVR’s/DVR’s) are covered by a 3 year back-to-base manufacturer warranty.

Our warranty is limited to the replacement of faulty items or parts and does not include damage due to incorrect fitting of parts or accessories, or damage due to mishandling the equipment once out of the box. All faults are sent to the manufacturer for inspection and diagnosis before a replacement is sent out.

Read more about the Terms & Conditions here – https://www.securityaustralia.com.au/terms-and-conditions/

Free Delivery* & Despatch Time

*Just spend over $100 to activate Fast Free Shipping!

Despatch Times: Products are despatched on the same day if the order was placed before 11am on any weekday, Monday - Friday. All other orders are processed and despatched within 24 hours or next business day.

Order Confirmation: Once you place an order, you will receive a confirmation email. This indicates that your order has been received in our system and is now being processed for dispatch. If your item is back-ordered or unavailable, we will notify you via email, and if we do not receive a response, we will attempt to contact you by phone as soon as possible. We value your time and strive to be prompt. If your item(s) are available for immediate shipment (within 2 days), we will process the charges and prepare the order for shipping.

Shipping Times: General shipping times for StarTrack, TNT and Allied couriers are between 1-3 working days from despatch. Longer delivery times may be caused by your package being held at your local courier depot that is beyond our control. Please contact us or the local post depot for confirmation.

Tracking Numbers: all tracking numbers will be emailed to you by our warehouse processing team within the day, after your order is despatched to our local courier.

Hikivision DS-K2602-GN/Aust Two Door Access Controller

$742.00 AUD
 per 
Warranty & support guarantee

Recently viewed products